miniTOC Analyzer
Total Organic Carbon monitoring using the classical flow-through concept. Efficient UV oxidation by the "direct surface" principle, combined with conductivity detection, guarantees fast, reliable monitoring of values.
- โ Low sample volume โ lower cost and waste
- โ 9-month UV lamp life guarantee โ 50% longer life
- โ Continuous measurement every 2 seconds โ fast reaction
- โ Offline measurement โ grab samples can be measured
- โ Up to 3 sample inlets โ very efficient
- โ Remote service โ online service diagnosis
Designed for TOC monitoring โ online and offline
The miniTOC uses the classical flow-through concept for online or offline TOC monitoring. Calibration and SST are easy and can be done by the user; online operation is interrupted briefly for system checks. The software enables the user to perform calibration and SST independently, and the programmable sequence ensures automatic procedure and data evaluation. Verification of TOC results follows USP and Ph.Eur requirements through periodic system suitability tests.
Configure the miniTOC for your process
Interval mode
Order the 4-input configuration (miniTOC pro); with a software upgrade, measure up to 3 loops sequentially.
Offline version
An offline configuration is available to analyse single samples.
Autosampler
In offline mode, the miniTOC pro is upgradable with an autosampler โ 15 positions for 100 mL vials.
Heat exchanger
Required if the medium temperature is higher than 50 ยฐC.
Pressure regulator
Required if the medium pressure is higher than 1 bar (pressure transducer).
21 CFR Part 11 software
Software with 21 CFR Part 11 conformity for pharma applications.
IP54 housing
Protects the miniTOC from dust deposits and water jets.
Check of sample flow
Initiates an alarm in case of inlet flow is zero.
IQ/OQ/PQ documents
Validation documents (conform and non-conform with 21 CFR Part 11 software).
miniTOC plus
The miniTOC plus series offers the same parameter properties as the miniTOC, but is equipped with a robust control unit that guarantees IP54 protection as standard โ increased protection against dust and splash water, making the devices versatile in use.
Main technical specifications
| Method & detection | UV-oxidation & conductivity |
|---|---|
| Sample volume flow | approx. 14 mL/min |
| Total Organic Carbon (TOC) range | 0.5 to 1000 ppb |
| Conductivity range | extended, sample up to 10 ยตS/cm |
| Related norms | USP, EP 2.2.44, DIN EN 1484 |
| Enclosure (miniTOC plus) | IP54 dust & splash-water protection |
Get a quote now
We'll help you choose the right TOC analyzer and answer any questions about your required configuration.